General Installation Information (see instruction sheet)

- Place drip pan (see sizing chart) under the water heater before installing a WAGS valve.
- Connect cold water supply line to "IN" port of the WAGS valve.
- Connect "out" port of WAGS valve to the "COLD IN" of the water heater.
- If water heater is gas fired attach included wiring harness between WAGS valve and gas valve.
Additional Materials Needed for Installation:

- Water heater drip pan or other suitable device that will allow the water to rise to a level of 3/4".
- Two 3/4" male sweat x thread adapters.
- Two lengths of copper (or other approved) tubing. Length will vary by installation – see step 9 on instruction sheet.
- Two to four (depending on the installation) 90° copper (or other approved) elbows.
| Drip Pan Sizing Chart |
| Water Heater Diameter |
Minimum Drip Pan Size |
| Up to 17.75" |
20" pan |
| 18" through 23" |
24" pan |
| 24.5" |
26" pan |
|